Description
Launch Tech USA American AVM Target Set ÔÇö Surround-View Calibration Targets for North American Vehicles
Engineered for around-view monitoring (AVM) system calibration on vehicles sold in the North American market, the Launch Tech USA American AVM Target Set (LAUADASAVM) is a brand-specific collection of calibration floor mats and accessories. For shops handling collision repair, camera removal and replacement, or windshield service on vehicles equipped with 360-degree or surround-view camera systems, this target set is the essential link between your X-431 ADAS frame and a fully verified calibration result.
Following a camera replacement or body repair, AVM calibration is not a step you can skip. Surround-view cameras that are even slightly out of alignment produce stitching artifacts, composite image blind spots, and ÔÇö on vehicles where the AVM feed drives parking assist logic ÔÇö outright active safety failures. This target set supplies the precise floor mat patterns that the vehicle’s calibration software requires to complete the procedure successfully.
Understanding AVM Calibration and Why Brand-Specific Targets Matter
Surround-view monitoring systems rely on four wide-angle cameras ÔÇö positioned at the front, rear, left mirror, and right mirror ÔÇö to assemble a composite bird’s-eye image. Achieving a seamless stitch requires each camera to be precisely aimed and its output mathematically corrected relative to the other three. The calibration software accomplishes this by identifying known geometric patterns printed on floor mats placed around the vehicle. If the mat pattern does not correspond to what that OEM’s calibration software expects for a given brand, the procedure will fail or generate an error code.
Launch’s LAC-series and AVM target mats are intentionally brand-specific. The American AVM Target Set addresses the North American vehicle brands and model families supported within the X-431 ADAS AVM calibration workflow. Confirmed brand and model-year coverage is visible through the vehicle selection screen in the X-431 ADAS software ÔÇö reach out to ADAS Calibration Tools before purchasing if you need to verify coverage for a particular make.
What’s Included
- AVM Floor Target Mats: Complete set of printed calibration pattern mats sized and patterned for supported North American vehicle brands
- Positioning Accessories: Alignment aids, clips, or reference markers included in the American AVM configuration (confirm exact contents with your sales representative for the current kit revision)
- Launch ADAS Compatibility: Built for use with the X-431 ADAS Mobile frame and X-431 ADAS calibration software ÔÇö this is not a standalone calibration system
Who This Target Set Is For
- Collision repair facilities servicing vehicles with surround-view cameras impacted by panel replacement or structural realignment
- Dealership service departments conducting camera R&R on AVM-equipped North American vehicles
- Independent repair shops that already have the X-431 ADAS frame and Throttle Professional scan tool and want to add AVM calibration capability without investing in a second complete system
- Auto glass and windshield shops on vehicles where the forward camera is part of the AVM array rather than a separate standalone ADAS camera
Prerequisites ÔÇö What You Must Already Have
The American AVM Target Set is a supplemental accessory kit, not an all-in-one calibration solution. Performing AVM calibrations requires the following:
- X-431 ADAS calibration frame (standard or Mobile/foldable version)
- X-431 Throttle Professional scan tool with an active ADAS software subscription
- A level calibration surface that meets Launch’s floor flatness specification
- This AVM target set covering the applicable vehicle brands
If you are equipping an ADAS calibration bay from the ground up, ask ADAS Calibration Tools about the Pro Plus, Premium, or Deluxe bundle configurations ÔÇö those packages combine the frame, target sets, and scan tool in a single purchase and are typically a better value than sourcing accessories separately.
When AVM Calibration Is Required
- Replacement of any of the four AVM cameras (front bumper, rear bumper, left or right mirror)
- Mirror assembly replacement or repositioning
- Front or rear bumper cover R&R that disturbs camera mounting positions
- Any collision repair that affects camera aim or orientation
- OEM service procedures following suspension geometry correction on AVM-equipped vehicles
Technical Notes
- Calibration type: Static (vehicle stationary, targets placed on the floor per software-guided prompts)
- Software: X-431 ADAS module ÔÇö the vehicle-guided procedure specifies mat placement distances and orientation for each brand
- Floor requirement: Level surface; specific flatness tolerances and lighting conditions apply per Launch’s setup documentation
- Coverage: North American vehicle brands supported in the X-431 ADAS AVM workflow ÔÇö confirm current model-year coverage with ADAS Calibration Tools prior to purchase
Why Buy From ADAS Calibration Tools?
- Launch ADAS specialists ÔÇö we have sold and supported this product line since its introduction in the North American market
- Free shipping on this order
- Free tech support at 800-123-4567 ÔÇö call before you buy if you need help confirming compatibility or identifying the right bundle for your shop
- Full manufacturer warranty honored on every Launch product we sell
- Straightforward upgrade guidance ÔÇö if you need the complete frame and target package together, we will give you the bundle price upfront before you buy individual accessories
Call 800-123-4567 for fast answers and expert guidance!





Reviews
There are no reviews yet.