ADAS Master Recalibration Solution

$37,144.38

In Stock — ready to ship
Flexible financing available — ask about pay-over-time.
Request a Quote
SKU: BODAS3000-1 Category: Brand:
Pro-Grade Equipment
OE-Level Accuracy
Fast Shipping
Expert Support
Share this product

Description

Robinair ADAS Master Recalibration Solution (BODAS3000-1)

Built for professional shops that need a complete recalibration solution, the ADAS Master Recalibration Solution covers forward-facing cameras, radar sensors, and related ADAS components following windshield replacement, collision repair, or any front-end or suspension work that displaces factory sensor alignment. This is the Bosch DAS 3000-family platform ÔÇö a precision calibration frame matched with target boards and radar reflectors, driven by guided on-screen calibration workflows that bring every sensor back to OEM specification.

Priced at $37,144, this system is a capital investment designed for high-volume collision centers, dealership body shops, and ADAS specialty operations that process enough camera and radar R&R work to make owning the equipment more practical than subcontracting calibrations or turning vehicles away.

What This System Does

Following any of the events listed below, a vehicle’s ADAS systems must be recalibrated before it can be safely returned to the customer:

  • Windshield replacement ÔÇö forward-facing cameras mount to the glass or the bracket bonded to it; removing the windshield breaks the calibration
  • Camera or radar R&R ÔÇö any sensor that is unbolted and reinstalled requires recalibration, even when it returns to the same mounting position
  • Front-end collision repair ÔÇö frame pulls, bumper replacement, and radiator support work can all shift radar mounts relative to the vehicle centerline
  • Wheel alignment or suspension work ÔÇö changes in ride height affect camera pitch; certain OEMs require recalibration following any four-wheel alignment

The system combines a calibration frame ÔÇö the rolling fixture that positions target boards in front of the vehicle ÔÇö with reflector panels and camera target boards. Using thrust-angle alignment markers and standoff distance references displayed within the guided software, the operator sets up the frame precisely for each vehicle. The software walks the technician through every step of the procedure, eliminating guesswork and the need to memorize OEM-specific workflows by vehicle. Active calibration commands are sent to the vehicle over OBD via a compatible scan tool.

What’s in the System

  • DAS 3000-family calibration frame ÔÇö heavy-duty wheeled fixture with adjustable height and width to accommodate vehicle classes ranging from compact cars to light trucks
  • Camera target boards ÔÇö precision-printed panels used in forward-facing camera static calibration procedures
  • Radar reflector ÔÇö used for front radar calibration, including adaptive cruise control and automatic emergency braking systems
  • Guided calibration software ÔÇö on-screen step-by-step instructions covering positioning, standoff distance, and OBD command sequencing
  • Compatible scan tool interface ÔÇö required to issue active calibration commands; confirm scan tool compatibility with your Robinair/Bosch representative prior to purchase if you do not already have a DAS 3000-compatible tool

Note: Specific vehicle coverage, supported scan tool models, and any accessories included beyond the frame and target kit should be confirmed at the time of order. Coverage expands through software updates ÔÇö contact ADAS Calibration Tools for the current OEM coverage list before purchasing.

Who Needs This System

This configuration is sized and priced for shops running consistent ADAS volume:

  • Collision centers handling 10 or more windshield jobs per month ÔÇö at $150ÔÇô$300 per subcontracted calibration, the breakeven on owning the equipment arrives quickly
  • Dealership body shops that already have scan tool infrastructure in place and need the frame and target side of the equation
  • ADAS calibration specialty shops building or expanding a dedicated lane for camera and radar work
  • Glass shops looking to bring calibration in-house instead of referring customers elsewhere

If your shop is processing fewer than five or six ADAS jobs per month, the numbers may favor a lower-cost entry-level system or continued subcontracting. Contact us and we’ll give you a straight answer on whether this configuration matches your current volume.

Why Static Calibration Equipment Matters

Dynamic calibration ÔÇö driving the vehicle at speed while the system self-calibrates ÔÇö is not accepted by all OEMs and does not apply to all camera types. Many forward-facing mono cameras specifically require static calibration with a target board: the OEM procedure defines the target, the standoff distance, and the conditions required, none of which can be replicated during a road drive. Without the correct target equipment, the options are to send the vehicle to the dealer or return it to the customer uncalibrated ÔÇö neither of which is acceptable when your shop is responsible for a completed collision repair.

Technical Notes

  • Calibration method: Static (target-based) for cameras; radar reflector method for front radar sensors
  • Frame adjustment: Width and height adjustable to span a range of vehicle classes ÔÇö exact minimum and maximum specs available on request
  • Software guidance: Step-by-step OEM-style procedure display; positioning markers for thrust angle and standoff distance
  • Scan tool requirement: A compatible Bosch/Robinair scan tool is required for active calibration commands ÔÇö confirm compatibility before ordering if you are working with an existing tool
  • OEM coverage: Contact us for the current vehicle coverage list; coverage is updated via software

Why Buy From ADAS Calibration Tools?

  • Specialist ÔÇö diagnostic and calibration equipment is our exclusive focus; it’s all we carry and all we support
  • Free shipping on orders over $99 ÔÇö freight for a system of this size will be quoted at checkout
  • Free tech support ÔÇö call 800-123-4567 and reach someone with hands-on knowledge of how calibration frames are configured and used
  • Full manufacturer warranty ÔÇö every system ships with the complete Bosch/Robinair warranty; ADAS Calibration Tools handles warranty support on your behalf
  • Honest upgrade guidance ÔÇö if the DAS 3000 is more than your shop needs right now, we’ll say so; if stepping up is the right move, we’ll tell you that too

Call 800-123-4567 for quick answers and expert assistance!

Additional information

Weight 0.0 lbs
Dimensions 0.0 × 0.0 × 0.0 in

Reviews

There are no reviews yet.

Be the first to review “ADAS Master Recalibration Solution”

Your email address will not be published. Required fields are marked *